(Rs.)
GECOMINDIA (Rs.Not Listed)
Automatic detection of syringe type.
Standby Function.
Last infusion memorized (more memory - optional)
8+ hours battery backup when fully charged.
Compatible syringes : 5 / 6m1 (optional), 10 / 12m1, 20 / 30m1, 50 / 60m1.
Bolus Rate: User selective with anti-bolus drive 8. Time is auto-calculative proportionate to bolus rate 8 duration of bolus function used.
KVO : Kvo - 0.1 to 3 ml user selective & 1ml/hr or set delivery rate, lower of either.
Online change of rate with automatic time reset in accordance woth remaining volumne.
3 Modes of operations (Upgradeable / Lockable):
Rate Mode: Rate calculated automatically (with increment of 0.1m1)
TECHNICAL SPECIFICATIONS
110mm LED / LCD colored display for distant view
Dimensions: 230mm (L), 110mm (H), 150mm (D)
Weight: 2kg without I.V. pole clamp
Power supply: 180 — 240V 50 / 60 Hz
Battery: 11.1v DC LI-10N 2200 mAh, charging only when equipment is switched ON.
DOSAGE / PURGE BOLUS CAPACITY
50 / 60m1 syringe: From 0.1m1 to 1800m1/hr
20 / 30m1 syringe: From 0.1m1 to 800m1/hr
10 / 12m1 syringe: From 0.1m1 to 400m1/hr
5 / 6m1 syringe: From 0.1m1 to 200m1/hr (5m1 syringe usages A optional)
Increment of 0.1m1/hr for all syringe capacity.
User can't set target volume more than the capacity of syringe type.
DRUG DOSE 1 PATIENT WEIGHT CAPACITY
Patient weight from 0.1kg to 99.9kgs with 0.1 kg increment (more capacity optional). Solution volume: From 0.1 to 999.9
Drug mass: From 0.01 to 999.9mg with 0.1 mg increment.
Dose: From 0.01 to 99.99ug/kg/min with 0.01 increment.
From 0.01 A 99.99mm/kg/hr with 0.01 increment.
PRESSURE SENSING
Occlusion: occlusion is managed in 3 stages.
Low (300mm/hg), Medium (500mm/hg), High (900mm/hg)
ALARMS
Syringe disengagement, Occlusion, Near empty, Empty, KVO, Low battery, Technical error. (All the above errors are indicated / expressed on screen in words, audio beep & visual red light)
Equipment status during infusion: Green LEDs (3) move & infusion blinks on screen when equipment is infusion, KVO & Bolus LEDs glow when in use & continuous beep when KVO is achieved.
All alarms ore expressed through LEDs, sound 8 screen written words.
ACCURACY
Works on +/- 2%, accuracy with correct calibration & syringe variability.
CERTIFICATION / STANDARD
Our equipment is CE certified, IEC 60601-1, IEC 60601-1-2 & IEC 60601-2-24.
We are ISO 13485:2016 certified.
GECOM
We are a registered MSME company, financed under KV1C (Scheme of PMEGP)
"BEAS" syringe pumps are designed, developed 8 manufactured in Indio.
Due to continous developments specifications may vary time to time for advancement.
"BEAS" syringe pumps are developed with technical association with CIPET, Bhopal 8 Shidore Microsys, Pune.